# 3-Node Heel Analog

**Purpose**

This feature is particularly effective in helping with trusses that have deflection issues. It may also be helpful for trusses with sliders where lumber fails in the first panel.

**Prerequisites**

Any truss with deflection issues

**Steps**

1. From **EnvData > Analysis > Overall Controls**, select **3-Node heel analog option**.
2. To enable this analog, set the value to **True**.


![](/images/csdirector-cstruss/resources/images/ts-3nodeheelanalog-329x187.png)

True uses the 3-node heel analog; false uses the typical heel network analog.