# Define Load Profile

**Purpose**

This feature is useful when the actual profile of a building does not match the profile of the truss, and the loading must be based on the building profile, not the truss profile. Common situations include:

- Piggyback - both the cap truss and base truss need to be loaded for the overall profile
- Back-to-back monos
- Any truss with non-structural overframing on the TC especially
- Some hip conditions or valley conditions where the shape is not built into the truss
- Stub conditions
- Bearing conditions where there is an exposed porch area


**Steps**

![](/images/csdirector-cstruss/resources/images/video-icon.png) Watch video

1. Click **Component**.


The **Component Loading** dialog displays.

![](/images/csdirector-cstruss/resources/images/ts-componentloading-dialog-loadprofilebutton.png)

1. Click **Load Profile**.


The **Load Profile** dialog displays.

![](/images/csdirector-cstruss/resources/images/ts-phantomloading.png)

Complete the following information:

**Show Load Profile on-screen** - when checked, an outline of the load profile overlays the actual truss on-screen

**Shortcuts** - when you click one of these options, information is entered on the dialog for you, based on either a Piggyback or Back-to-Back Mono condition. You may need to edit this information based on your truss profile.

- Piggyback - when selected, the following information is populated in the Load Profile dialog:
- Span = the physical truss span
- TC Profile = the physical truss, but only the heel height and first TC pitch are used. For example, if the physical truss is **ha600 12 10 0 150608 -12e** the Load Profile TC profile is **ha600 12**.
- BC Profile = the physical truss
- Cants = the physical truss
- Offsets = 0 for both X and Y
- Alignment = Left Heel


![](/images/csdirector-cstruss/transparent.gif)Base Truss Example

Loading is based on a peaked truss

![](/images/csdirector-cstruss/resources/images/ts-loadprofilesample1.png)

![](/images/csdirector-cstruss/transparent.gif)Cap Truss Example

![](/images/csdirector-cstruss/resources/images/ts-loadprofile-captrussex.png)

- Back-to-back Monos - when selected, the following information is populated in the Load Profile dialog:
- Span = the physical truss span x 2. For example, if the physical truss is a 40 foot span, the Load Profile span = 80 feet
  - If there is a right overhang, that distance is included in the original span. For example, a 40 foot span with a 2' overhang = 42' total, making the Load Profile span = 84 feet. ![](/images/csdirector-cstruss/resources/images/ts-rightoh-on.png) ![](/images/csdirector-cstruss/resources/images/ts-rightoh-off-445x192.png)
  - The Match Left OH check box is selected by default, but can be unchecked if the right mono is not a match with the left mono.
- TC Profile = the physical truss, but only the heel height and first TC pitch are used. For example, if the physical truss is **ha600 12 10 0 150608 -12e** the Load Profile TC profile is **ha600 12**.
- BC Profile = the physical truss
- Cants = the physical truss; whatever is used for the left cantilever entry is also used for the right cantilever entry. For example, if the physical truss has a 3-foot cantilever left, and a 0 foot cantilever right, the Load Profile will have both left and right cantilevers = 3 feet.
- Offsets = 0 for both X and Y
- Alignment = Left Heel


![](/images/csdirector-cstruss/transparent.gif)Left Mono Example

When you click the Back-to-back Monos option, the span is automatically doubled. Creates a symmetrical load profile based on the actual truss.

Loading will be based on a 48' truss (rather than 24').

![](/images/csdirector-cstruss/resources/images/ts-loadprofile-monoexample2-1024x332.png)

![](/images/csdirector-cstruss/resources/images/ts-loadprofile-monoexample-1005x362.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** This feature does not affect loads that are controlled by web patterns.