# Extended Chord Bearing Analysis

ANSI/TPI 1-2022 includes a new method for determining allowable top chord bearing reaction limits. This functionality was added in Truss Studio 2023.9. This method does not replae the current prescriptive method, but provides an alternative calculation method that users can choose to apply This method applies to any top chord bearing trusses, floor or roof, Wx2 or 2xW.

Instead of a prescribed limit, the actual situational conditions are used to calculate a maximum allowable reaction for top chord bearing trusses, based on:

- Lumber size, species, and grade
- Gap size (no longer limited to ½ inch).
- End webbing geometry.
- Plate size and position on the joint


![](/images/csdirector-cstruss/resources/images/ts-extendedtcbearinganalysis.png)

When applying this method of calculation, Truss Studio does the following:

- Recognizes the current described geometry and design results
- Analogs the condition like a tail-bearing
- Plates the end joint with a required 20% reduction in plate gripping allowables


After the plating is known, four different allowable reactions are calculated based on:

- Bending of the chord
- Shear in the chord
- Rolling shear in the plate
- Bearing area (compression perpendicular to grain)


To see more information about these reactions, right-click on EnvData and select Generate All Audits. Run the truss and select the Eng Calcs tab.

The minimum of these four reactions becomes the maximum allowable reaction for that condition. The maximum reaction is reported, and the truss passes or fails when the actual reaction is compared to the maximum.

![](/images/csdirector-cstruss/resources/images/ts-maxallowreaction.png)

To use this feature, follow these steps:

1. Set **EnvData > Analysis > OverallControls > Use TPI analytical method for Extended TC** to **True** (also available from the right-click EnvData button).
2. Use the [End Conditions/Descriptions](/csdirector-cstruss/help-center/design-view/end-description) dialog to specify the condition, along with the Profile command lines and Additional Commands.
3. Use Plate Monitor Options to attempt different plates/positions.


If the condition fails, try the following solutions:

- Adjust plating
- Upgrade lumber size/grade
- Add/remove members
- Lessen the gap
- Reduce loading (including smaller truss spacing, etc.).


Note the following limitations of this feature:

- Lumber is not upgraded if bending is the limiting factor
- Plate cannot be upsized if the current plate is the limiting factor
- Anything else in TPI-2022 is not included; this will be available in a later release.