# Load Template Manager

![](/images/csdirector-cstruss/resources/images/video-icon-41x42.png) Watch videos

IRC vs. IBC Building Codes and Live Load Reductions

- Part 1
- Part 2


Load Template Manager - General Usage

Select Ohio Building Code

Updating Existing Jobs to IRC/IBC 2024

![](/images/csdirector-cstruss/transparent.gif)**Important Note Regarding ASCE7-22 and IRC/IBC 2024 Compatibility:**

The required loading standard, which is ASCE7-22 under the new code, is not compatible with previous versions of IRC/IBC and ASCE7. Because of the complexities regarding the new standards and new required parameters, it is not possible to simply convert an existing job by selecting the new Building Code or Load Standard in Load Template Manager; you must make additional adjustments to loading.

For existing jobs with Load Transfers, you must update the load transfers on all girders after making any changes to the truss loading.

- For [Snow Loads](/csdirector-cstruss/help-center/design-view/loading/snow-load), you must change/update:
  - Ground Snow Load
  - Thermal Condition
  - Winter Wind Parameter
  - Roof R Value (depending on the Thermal Condition selected)
- For [Wind Loads](/csdirector-cstruss/help-center/design-view/loading/wind-load), you may need to adjust the Wind Speed
- For existing jobs with load transfers, you must update the load transfers on all girders after making any changes to the truss loading.
- Additionally, for new jobs, it is imperative that you correctly adjust all wind and snow loading parameters in the Load Template for the project. Use the ASCE Hazard Tool to determine adequate loading for the project location if it is not clearly specified on plan documents by the Building Designer.


The easiest way to make loading changes to all trusses after selecting a new building code is to edit the Project EnvData file:

1. In Director under **Presets > Design Application**, open **Load Template Manager**.


![](/images/csdirector-cstruss/resources/images/ts-designapp-load-template-mgr-859x491.png)

The Load Template Manager displays.

1. Locate the load template for the project.
2. Make a copy of the template and select the new Building Code to apply to the project.


![](/images/csdirector-cstruss/resources/images/ts-load-temp-manager-for-project.png)

1. Adjust [Wind Loads](/csdirector-cstruss/help-center/design-view/loading/wind-load) and [Snow Loads](/csdirector-cstruss/help-center/design-view/loading/snow-load), as necessary.
2. Save the copy of the load template and click **OK** to close the window. Close Preset Manager.
3. In Director under **Components**, select all trusses for the job.
4. Click **Reanalyze Truss**.


The **Reanalyze Selected Trusses** dialog displays.

1. In the drop down list, select the copy of the load template that you just edited.


![](/images/csdirector-cstruss/resources/images/ts-reanalyze-trusses-director.png)

1. If you need to maintain the same lumber, plates, and actual sizes, select the **Hold Lumber**, **Hold Plates**, **Hold Actual Sizes** check boxes under **Allow Lumber and Plates to change?** Doing this may result in some failed trusses since the loading values will have changed. If you do not need to maintain the same lumber, plates, and actual sizes, uncheck those boxes. Truss Studio will adjust lumber and plates to accommodate the new loading template but may still fail trusses that no longer work.
2. Click **Re-analyze**.


A message displays indicating which trusses passed or failed.

1. Make adjustments to trusses, as needed.


Note that the above process only updates the trusses but does not update any layouts. To update layouts:

1. Open the layouts and select the Apply New Load Template option.
2. Select all trusses to apply the new template to and run with **Analyze All**.
3. Re-save the layout.


#### About Load Template Manager

Use Load Template Manager to define loading in various conditions, such as wind and snow. You can also select building codes and other design standards on this window. Any changes to the load template apply only to the current project (loading is applied to trusses based on the active load template at the time of truss input). Therefore, these settings should be defined prior to working on a job.

You can create multiple Load Templates by entering a new Load Template Name, defining the specific criteria, and clicking Save. All Load Templates are available in the drop down list on the main Truss Studio workspace.

Loading is assigned to trusses based on the active load template at the time of truss input.

A sample load template is shown below.

![](/images/csdirector-cstruss/resources/images/ts-loadtemplatemanager.png)

**Deflection Control:** Deflection is the degree to which a structural element is displaced under a load. Select Roof or Floor.

**Risk Category:** Select a risk category of I, II, II or IV. Risk Categories are defined by the building code to categorize the potential for injury or death in case of a failure. Agricultural buildings are low risk, single-family house moderate risk, public buildings higher risk, emergency infrastructure highest risk.

**Building Code:** Select a Building Code from the drop down list. The building code is the local law regarding construction. You can select IRC, IBC, CRC, CBC, and others. Note that when changing building codes, the ASCE7 and TPI requirements may automatically update to the minimum requirements. Codes/standards for IBC-2024, IRC-2024, ASCE 7-2022, and TPI 1-2022 were implemented in 2024.7and can be selected from the dropdown list.

**Load Standard:** Provides requirements for general structural design and includes means for determining dead, live, soil, flood, wind, snow, rain, atmospheric ice, and earthquake loads, as well as their combinations. Codes/standards for IBC-2024, IRC-2024, ASCE 7-2022, and TPI 1-2022 were implemented in 2024.7and can be selected from the dropdown list.

**Design Standard:** Defines the national standard for metal plate connected wood truss construction

**Pitch (DL adj):** Select the pitch for the truss from the drop down list. Note that any truss with a pitch greater than this value will add additional dead load to the truss.

**Min Cant:** The maximum value that will be considered a loading zone; the largest value allowed is 6 inches. This means that a truss with a cantilever shorter than that value does not have additional loading for the cantilever area.

Building Loads

Click the check box next to a load type to enable or disable the load type. To edit load settings associated with the current template, click a Building Loads button to launch the appropriate window and make changes.

- [Standard Load](/csdirector-cstruss/help-center/design-view/loading/standard-loads-dialog)
- [Wind Load](/csdirector-cstruss/help-center/design-view/loading/wind-load)
- [Snow Load](/csdirector-cstruss/help-center/design-view/loading/snow-load)


**Unbalanced live (user):** This load creates two separate **zones** on both sides of the truss peak (default functionality) or a user-defined location. One zone receives the **Full** live load, the other zone receives the **Reduced** live load. Generally, these factors are set to 1.00 and 0.00, but could be 1.25 and 0.50, or any other combination of factors, within the parameters allowed. Any factor used is multiplied on the actual specified live load to determine the load to apply in each zone. When selected, a note is added to the TDD under the Loads Summary section indicating the location of the unbalanced TCLL and the factors applied. Note that **peak** is defined as the high point of the top chord.

![](/images/csdirector-cstruss/resources/images/ts-userdefinedunbalanced-tdd.png)

**NonConcurrent BCLL:** Turn the nonconcurrent bottom chord live load on or off. This is the code required for 10 PSF non-concurrent BCLL, that is sometimes optional. For example, it is not required on agricultural trusses. As a general rule, this should always be turned on. If the BCLL is required to be greater than 10 PSF, the factor applied to this load case can be adjusted in [User Load Groups in Load Combination Manager](/csdirector-cstruss/help-center/design-view/loading/user-load-groups-in-load-combination-manager).

**Unbalanced Snow:** The code required for snow drift loading about ridge locations, which is sometimes optional. For example, some jurisdictions allow the ground snow load to be used as the roof design snow load, or some other value, and do not require unbalanced drift loading. As a general rule, this should be turned on anytime that snow loads apply.

**Use Area Reduction:** Controls tributary area calculation for IRC/IBC Live Load Reductions. If you select an IBC code, this option displays. This is primarily for wide on-center spaced trusses (agricultural trusses, for example) to automatically reduce the required live load when the tributary area is greater than 200 sq. ft. This is an additional reduction to the already included pitch reduction. Read more about Tributary Area (from SBC Magazine).

**20 psf Storage:** The 20 PSF attic storage load required by code, whenever the space between the top of the bottom chord and any member above it is at least 42” tall and 24” wide. Formerly known as the BOCA load check. Note that 20 PSF storage loads and mechanical unit loads are separately considered when they apply in the same location. Turning off the Mech Load (or the LSC) causes that load to be removed from all load cases, including user load cases (copied or created from scratch). Note that the application of 20 PSF storage load can be verified using the [Applied Loads View](/csdirector-cstruss/help-center/design-view/loading/view-loads).

30"x30" Moving Loads

Each of these check boxes works independently of the others, and each produces a set of moving load cases. If all three are selected, there will be three different sets of load cases. For more information about how these loads work, see Moving Point Loads.

- 300 lbs TC Maintenance: applied load is 48 PSF
- 200 lbs BC Man Load: applied load is 32 PSF
- 2000 lbs BC Safe Load: applied load is 320 PSF


**300 lb TC/BC Person**: This load is intended to cover a person weighing up to 300 pounds, standing in the attic space on a single truss. It is not expected to control the design, typically, but it may limit the panel length allowed, especially for smaller lumber sizes.

On Feb 6, 2026 the interpretation of this setting was amended. The new setting (default) uses the conditions and definitions outlined in the ‘TPI-TAC Technical Interpretation - Section 6.2.2.5’ issued 2/6/2026 (the full technical interpretation issued by the TPI-TAC committee is available here). This updated interpretation includes new load reduction allowances (due to truss spacing, applied purlin spacing, and/or accessible area checks), as well as a new definition of the 18' span limit set via the **Disable TPI person loading when not applicable (spans <18')** EnvData setting, allowing for a more optimized design. See [Overall Controls](/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/overall-controls-settings).

Read the full technical interpretation from the Truss Plate Institute.

When the default setting is selected and the **300 Lbs TC/BC Person** check box is enabled in Load Template Manager, the following occurs:

- The following message displays on the Warnings audit tab: **Person loading has been applied according to TPI interpretation (Feb 6, 2026) as requested in EnvData**.
- A note appears in the (Design) Loads Summary section of the TDD: **Person loading has been applied based on the ‘TPI-TAC Technical Interpretation - Section 6.2.2.5’ issued 2/6/2026**.


**Sprinklers**

Click the **Sprinklers** button to display a dialog where you can define sprinkler loads. See [Sprinkler Loads](/csdirector-cstruss/help-center/design-view/loading/sprinkler-loads) for information.

See also [Apply Load Template](/csdirector-cstruss/help-center/layout-view/apply-load-template).