# Load Template Manager - Snow Load

Roof snow loads are computed in pounds per square foot (PSF) using the ground snow load as the basis for calculation. If building a roof on a structure in a region that receives snowfall, you must consider snow load when choosing the design and materials. See ascehazardtool.org for additional useful information in determining snow loads.

Define Snow Load settings on the **Snow Load** dialog.

![](/images/csdirector-cstruss/resources/images/ts-snowloaddialog.png)

- **Terrain Category** - Wind and Snow must use the same exposure category. If you change the wind Exposure Category to C, the snow Terrain Category is also changed to C, and vice versa. Whatever is selected in one dialog will be applied to both. This prevents accidental differences that are not in compliance with building codes.
- **Snow Exposure** - determines the protected nature of the building site from surrounding trees, terrain and other buildings. The options are Exposed, Partially Exposed, and Sheltered. If there are no trees or other structures around, the site is Exposed. If the site is located tightly in among trees (like a cabin in a forest), then the site is Sheltered. All other sites are considered to be Partially Exposed, which is the most common.
- **Thermal Condition** - This relates to the amount of heat and insulation provided in the attic space (the area between TC and BC, not an attic truss). The actual factor for the thermal condition is included in parentheses and that value is also output to the TDD. There are four options
  - AllExcept (varies) is the most common setting for residential construction. Beginning with ASCE-22, this is based on the insulation value of insulation in the attic space. See ASCE-22, Table 7.3-3.
  - AboveFreeze (1.1) is used if the structure will be heated and the insulation is such that the attic space will always be kept above freezing.
  - Unheated (1.2) is used when there is no heat consistently provided in the building at all, such as AG buildings or sheds.
  - Greenhouse (0.85) is used when there is no barrier at the ceiling and the building is heated, such that the attic space essentially is the same temperature as the rest of the building.
  - If the condition is unknown, or if AboveFreeze, Unheated, or Greenhouse do not apply, use AllExcept.
  - Thermal condition information is also shown on the TDD output in the **Thermal Condition: <####**> note.
- **Apply Rain Surcharge** - ASCE 7 requirement that applies occasionally, only when the Ground snow load is 20 PSF or less, but not zero. An additional 5 PSF rain load is added to the snow load for this requirement, but only on very low-sloped roofs as determined by ASCE 7 formulas.
- **Winter Wind Parameter** - This value affects how snow drift loads are calculated. This factor represents the percentage of time that wind speed is above 10 mph during winter months. This data is saved to the TDL file with when EnvData > [Other](/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/other-settings) > Save truss export data in truss file is enabled. For additional information, refer to ASCE7-22 Section 7.6.1 and Figure 7.6-1.
- **Roof R-Value** - This value displays for certain Thermal Conditions selected. Select a value from the drop down list or enter the appropriate insulation R-value. This is a new option based on ASCE-22 updates.
- **Ground Snow Load/**Specified **Roof Snow Load, psf** - select a value from the drop down list
  - You can enter either the Ground Snow Load value or the Specified Roof Snow Load value (flat roof snow load).
  - If Ground Snow load is used, Truss Studio will use the ASCE 7 formula to calculate the roof snow load amount to apply to the designs.
  - If Specified Roof Snow is used, Truss Studio applies that roof load to the designs instead of using a calculated amount. In either case, reductions for pitch, area, and slippery-roof still may apply.
  - Maximum allowable snow load PSF (ground or roof) is 500
  - Beginning with ASCE 7-22 there is an additional 70% factor applied to snow loads when you create load combinations.
- **Apply Ice Dam Loadcase** - ASCE 7 required load case when the roof is warm enough to melt snow above the livable area and allows water to drain over the eaves (overhangs) and re-freeze there due to the eaves not having heat from below. Depending on the insulation value above the ceiling and the ventilation in the attic, this load case may be required. If required, an additional load case with 2 times the flat roof snow load on overhangs only is created.
- **Unobstructed slippery roof surface** - allows snow loads to be reduced at a greater rate based on the pitch of the roof, if the roof is “slippery” and “unobstructed” (as defined in ASCE 7). The “Dashed Lines” language is used because the allowed reduction for unobstructed slippery roofs is shown in a chart in ASCE 7 as a dashed line, as opposed to a solid line representing all other roof surfaces. This option may apply on a metal roof if there is nothing blocking the snow from sliding off anywhere from the peak to the eaves.
- **Report Roof Snow Load as Live Load on output** - allows the snow load to be reported on the TDD as the live load, without actually changing the live load to equal the snow load. This is a reporting issue only, and will not change any of the loading functionality of the program.


**Note:** Confirmation is required if the live load is used as a snow load, but the actual snow load is either turned off or set to a lower value.

![](/images/csdirector-cstruss/resources/images/ts-confirmsnowloading.png) ![](/images/csdirector-cstruss/resources/images/ts-confirmsnowloading-2.png)