# Verify Load Transfers in Design View

**Purpose**

When you open a girder truss with load transfer loads on it in Design view, Truss Studio Design will automatically verify the loads.

**Steps**

![](/images/csdirector-cstruss/resources/images/video-icon-42x43.png) Watch video

1. Open or create a girder truss.


Truss Studio Design view automatically verifies load transfers.

![](/images/csdirector-cstruss/resources/images/ts-loadtransfers-verified-1045x380.jpg)

The application finds all child trusses associated with the girder truss. Truss Studio compares reactions stored in child trusses to point loads applied to girder truss, and warns if there is a mismatch. A message displays for each child truss that is a mismatch.

![](/images/csdirector-cstruss/resources/images/ts-loadtransfermismatch-1063x538.jpg)

1. Click **Yes** to update trusses.


If child trusses are missing, a warning displays that the load transfers could not be verified.

This note may also display if you have an existing job that was created in a previous version, have updated to a newer version, and then opened a girder design. This means that the data saved to the truss files is missing (because it didn’t exist in previous releases).

You can do one of the following:

- You can ignore the message if no other changes have been made.
- You can fix the issue by rerunning all trusses in the updated Truss Studio version and resaving them (even if there are no changes); that will create the data needed for the program to verify loads.


![](/images/csdirector-cstruss/resources/images/ts-loadtransfermissinginfo-913x462.jpg)

If you have a girder truss already open when child trusses are changed, you can press Shift and click Run for the girder truss; Truss Studio will re-verify the loads and allow you to update without having to close and reopen.

**Related Topics**