# Load Template Manager - Wind Load

Define Wind Load settings such as Design, Exposure Category, Building Type, and Wind Speed on the Wind Load Dialog.

See ascehazardtool.org for additional useful information.

![](/images/csdirector-cstruss/resources/images/video-icon-37x38.png) Watch videos

Using MWFRS when purlins are not applied

Using Ground Elevation Factor

Building Type & C&C Loading for ASCE 7-22

![](/images/csdirector-cstruss/resources/images/ts-windloaddialog-groundelev.png)

- Design Method - Select a design method of Hybrid MW, Hybrid CC, or MWFRS (Main Wind).
- ASCE7 MWFRS - designs for MWFRS and C&C but only displays MWFRS on output
- ASCE7 C&C - designs for MWFRS and C&C but only displays C&C on output
- MWFRS - designs for MWFRS only and displays MWFRS


![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note**: A warning note displays on-screen when MWFRS is used and purlins are not applied.

- MWFRS must be selected as the Wind Design Method; and
- Sheathing must be selected as the bracing method for any part of the top chord.  ![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) Note that this does not apply to Canadian designs; ASCE7 load standards are for US applications only.  ![](/images/csdirector-cstruss/resources/images/ts-trussnotccwindloads-859x520.png)
- Exposure Category - Exposure of the building, based on the terrain (open area, suburb, etc.) and should be dictated by the building designer on any set of plans. If not specified, the default should be “B” or whatever the local building jurisdiction expect.


![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** Wind and Snow must use the same exposure category. If you change the wind Exposure Category to C, the snow Terrain Category is also changed to C, and vice versa. Whatever is selected in one dialog will be applied to both. This prevents accidental differences that are not in compliance with building codes.

- Building Type - Enclosure category of the building, based on the number and size of openings in the building walls; should also be dictated by the building designer on the plans. **Encl** (for Enclosed) is the default. When ASCE7-22 is the selected Load Standard, the Wind Load dialog has a Partially Open option for Building Type. This setting is the same as Partially Enclosed.
- CC Truss Location - Indicate whether the truss is an Interior Truss or End Zone Truss
- Wind Speed - Select a wind speed from the drop down list. The maximum allowable wind speed is 300 MPH. If ASCE 7-05 is selected, the minimum wind speed allowed is 85 MPH. If ASCE 7-10 is selected, the minimum wind speed allowed is 100 MPH. If the wind speed selected is too low, an error message displays and you must increase the level.
- Mean Roof Height - Select the mean roof height from the drop down list. Mean roof height is half the height of the tallest ridge line above the plate line, added to the wall height. Anything higher than the required height is acceptable. For example, 6/12 on a 34' truss with standard 2x4 heels is just under 9' tall; (4.5' + 8' = 12.5, approximate mean roof height).
- Note that this is not the plate line height. Whatever is selected or entered here is what will be used in subsequent calculations, regardless of the actual truss height.
- Apply to Left/Right End Vert - These check boxes control whether an end vertical is exposed to wind. Generally these should be turned on at the project level; you can turn them off for a specific truss when either or both end verticals are not exposed to wind.
  - ![](/images/csdirector-cstruss/transparent.gif)A visual indicator displays in status bar for wind loads applied to left and right ends of a truss.L = Wind Loads applied to Left End Vertl = Wind Loads not applied to Left End VertR = Wind Loads applied to Right End Vertr = Wind Loads not applied to Right End Vert![](/images/csdirector-cstruss/resources/images/ts-windloading-endvertwind-784x615.png)
- Truss within MRH of end - This option indicates that a truss is within the end zone area for purposes of wind loading. MRH = Mean Roof Height.
- Hurricane Prone Region - When this option is enabled, a note is output on the TDD specifying, "Hurricane Prone Region."
- Ground Elevation - This option represents the Ke Ground Elevation Factor for wind load calculations from ASCE-7-16, Table 26.9-1 and is available only when using ASCE 7-16 or newer. Trusses designed using this reduction in wind pressure are not adequate for any elevation lower than the defined parameter. When this option is used, the Ke factor displays in the Wind Load Specs dashboard area, after the Kzt factor. If you do not use this option, you will get slightly higher uplift in your designs.
![](/images/csdirector-cstruss/resources/images/ts-windloadtdd.png)
![](/images/csdirector-cstruss/resources/images/d-kewindmessage-804x113.png)
- Building Length/Width - Select the length/width from the drop down list. Building width and length dimensions for wind load can be set up to 999 feet. If these dimensions are set to zero, the building dimensions from the layout are automatically used.
- Overrides - Lets you specify actual material weights for wind load cases, instead of having the program use the 60% design dead load rule required by ASCE 7, when the material weights are unknown.
  - Specified Uplift, psf - Create a “net uplift” load case to apply. For example, plans sometimes call for “wind load 115 MPH . . etc. . . per ASCE 7-10, but not less than 10 PSF uplift." This setting lets you enter the 10 PSF requirement. You also have the ability to enter a negative value for uplift; the result is a downward net uplift.
  - Kzt per EOR (Topographic Effect Factor) - This is used only when the building designer (or EOR – engineer of record) has specified something non-standard. 1.00 is the default for this, and should only be changed when required/allowed by the EOR. As stated, it is a calculation factor based on the Topographic Effect of the building site.