# Load Transfer Connections without Layout

**Purpose**

Ability to take reaction from child truss and transfer as point load to girder. Use this feature without a layout or to adjust loads on any trusses/girders from layout.

**Steps**

![](/images/csdirector-cstruss/resources/images/video-icon.png) Watch video

1. Open a girder truss.


![](/images/csdirector-cstruss/resources/images/ts-girdertruss-transferloads.png)

1. Open another truss from which to transfer loads (child truss).


![](/images/csdirector-cstruss/resources/images/ts-girdertruss-transferloads-child.png)

You must have both trusses open at once in order to transfer loads.

In this example, the loads from the stub end of the child truss will be transferred to the girder truss.

1. Return to the girder truss.
2. Open the **Component Loading** dialog and click **Load Transfer**.


![](/images/csdirector-cstruss/resources/images/ts-comploading-loadtransfer.png)

The **Load Transfer Point Load** dialog displays and options appear under the **Child Truss Candidates** section.

1. Select an option. For this example, T01 is selected.


![](/images/csdirector-cstruss/resources/images/ts-childtrusscandidate-ex.png)

After you select that option, the **Child Truss Bearings** dropdown is populated.

![](/images/csdirector-cstruss/resources/images/ts-childtrussbearings.png)

1. The second option in the list is selected for this example.
2. Enter a location for the loads.


![](/images/csdirector-cstruss/resources/images/ts-childtrussexample2.png)

1. Click **Save** to save the load information.


![](/images/csdirector-cstruss/resources/images/ts-childtrusssavedload.png)

1. Click **OK** to close the dialog.
2. Click **OK** to close the **Component Loading** dialog.


The load is applied to the girder truss.

![](/images/csdirector-cstruss/resources/images/ts-childloadapplied-1.png)

You can continue to select loads from the child truss and apply them to the girder truss.

1. Return to the **Load Transfer Point Load** dialog and select the load transfer information you previously created.
2. Make one or more copies and edit, as needed. For this example, loads need to be applied to the girder truss at 4', 8', 6' and 10' so the load information has been copied four times.


![](/images/csdirector-cstruss/resources/images/ts-childloadcopied.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) Note that user-controlled loads are designated with a **C**. If a load was transferred from Layout, it is designated with a **T**. All loads designated with a **T** are automatically updated; loads with a **C** are not and must be manually updated.

1. Edit the location for each, as appropriate, and click **Save** after each edit.
2. Click **OK** to close the dialog.
3. Click **OK** to close the **Component Loading** dialog.


The loads are applied to the girder truss.

![](/images/csdirector-cstruss/resources/images/ts-childloadapplied-2.png)

**Updating Load Transfers**

If you need to update these loads at a later time, because the child truss loads change, you do not need to have both trusses open at once.

1. Once the loads are updated on the child truss, open the girder truss and press **Shift** while clicking the **Run** button.


A message displays.

![](/images/csdirector-cstruss/resources/images/ts-girdertruss-updatemessage.png)

1. Click **Yes**.


The loads are automatically updated.