# Using Treated Materials

**Purpose**

Fire-Retardant Wood Treatment (FRT) and Pressure Treated (PT) materials are available in Material Catalogs or Project Materials. More information on material catalogs can be found in [Material Catalogs Overview](/csdirector-cstruss/help-center/director-online-help/project-list-section/d-materialcatalogs)

**Steps**

When choosing materials for a project requiring pressure treated or fire treated materials, you must choose materials with PT or FRT in the species name.

**Note:** MCQ and MCA are types of pressure treatments.

![](/images/csdirector-cstruss/resources/images/ts-frtspecies.png)

When materials with pressure or fire treatments are required, there are four EnvData settings that must be set:

1. OneTrussControls > Treated lumber used


True/False: True forces the program to apply the reduction factors for plating (see 2., below) and places a note on the engineering drawing.

![](/images/csdirector-cstruss/resources/images/ts-frttreatedlumberteeth.png)

1. Plating > OverallCriteria > Treated Lumber tooth holding reduction factor (Fire-Retardant, PT, other)


Min: 0.50 Max: 1.00 Default: 0.80 These factors can be found in the Evaluation Service Report (ESR) specific to the materials used in the truss design. Factors are supplied by the agency performing the lumber treatment.

1. OneTrussControls > Lumber has been incised


True/False: True forces the program to apply reduction factors for plating (see 4., below) and places a note on the engineering drawing.

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** Treated lumber may or may not be incised, depending upon your supplier; knowing your materials is critical for proper truss manufacturing.

![](/images/csdirector-cstruss/resources/images/ts-frtincisedlumber.png)

1. Plating > OverallCriteria > Lumber-has-been-incised factor


Min: 0.50 Max: 1.00 Default: 0.90 These factors can be found in the ESR specific to the materials used in the truss design. Factors are supplied by the agency doing the lumber treatment.

The lumber values used in CS Truss come from the lumber chosen in Director and assigned to the truss. If Project Materials are all fire-retardant materials, the values of those materials will be less because of the lumber itself and not because of a setting in Truss Studio.

The plating values used in CS Truss come from Truss Studio and are reduced because of the Treated lumber and Incised settings and not because of fact that treated lumber was used.

**Related Topics**

[Material Catalogs Overview](/csdirector-cstruss/help-center/director-online-help/project-list-section/d-materialcatalogs)