# Control Uplift Reactions

**Purpose**

Adjust truss designs to alleviate uplift conditions at bearings.

![](/images/csdirector-cstruss/transparent.gif)More about uplift reactions

Uplift reactions are the result of a set of conditions that generally includes load types, load combinations, bearing locations, and web patterns. In most cases, especially those involving wind load combinations, uplift reactions are relatively small and can easily be resolved through the specification of standard Seismic and Hurricane Ties, such as Simpson’s H2.5A. In other cases, such as drag load combinations, uplift reactions can be relatively or extremely high (> 10,000 lbs). Furthermore, gravity load combinations in conjunction with interior bearings that are relatively close to an exterior support, can create high uplift reactions that require additional design considerations: the allowable loads for Simpson’s Seismic and Hurricane Ties, as well as Girder Tie-downs, are based on a 1.60 Load Duration Factor, and specifying tie-downs for a gravity uplift condition requires that the duration of load associated with the load combination creating the uplift condition be taken into account.

Alerting the truss designer that a high uplift condition exists during the design phase of the component may have benefits. In some cases, the design can be altered to alleviate the high uplift condition. And, if the component design cannot be changed to alleviate the high uplift condition, the truss designer can alert the Building Designer or EOR that the condition exists and that additional design considerations may need to be accounted for when specifying a connection; this is especially true if a high uplift reaction occurs at a hanger support.

**Steps**

1. Navigate to EnvData > Analysis > Overall Controls > Design for no uplift at interior supports.


This setting controls whether bearings receive uplift.

- When set to True, the left-most and right-most bearings receive uplift; all other intermediate bearings are set for no uplift.
- Also, the No Uplift control in the Bearings dialog is disabled. In order to use this control, set the EnvData setting to False, then select the specific bearings for uplift. At least two bearings must be allowed to have uplift.


The sample truss below shows the EnvData option set to True. Uplift reactions are reduced at the interior wall bearings.

![](/images/csdirector-cstruss/resources/images/ts-uplift-ex2.png)

When the EnvData setting is False, the No Uplift check box on the Bearings dialog becomes available.

1. Open the **Bearings** dialog.
2. Select the bearing for which you want to remove uplift and check the **No uplift** check box. This means no uplift connection at those bearings is required.


![](/images/csdirector-cstruss/resources/images/ts-nouplift-bearings.png)

1. Save the bearing.


When you reanalyze the truss, uplift is removed for the selected bearings.

In the sample truss below, the setting is False and there are uplift reactions at selected bearings.

![](/images/csdirector-cstruss/resources/images/ts-uplift-ex1.png)

If you attempt to remove uplift for all bearings, an error displays. You cannot close the Bearings dialog until you correct the error.

![](/images/csdirector-cstruss/resources/images/ts-uplifterror.png)

When the No Uplift checkbox is selected for continuous bearing trusses, all intermediate supports between the ends of the continuous bearing will not be used to resist uplift, whether from gravity, wind, seismic or any other applied loads.

**Related Topics**

[Add Bearings](/csdirector-cstruss/help-center/design-view/bearings/bearings)