# Gable Truss Design: Apply Additional Loading for Gable Rake Overhangs

**Description**

When a gable truss has a rake overhang exceeding half of the on-center spacing, it is underloaded.

**Design Practices**

Gable end trusses may require additional top chord load to account for a rake overhang. A common design mistake is to assume the total area tributary to the top chord of the gable end truss equals the rake overhang length plus 1/2 the gable end truss spacing. However, if the gable end truss has a spacing of 24” o.c. and is positioned no more than 24” away from the first common truss, then the maximum rake overhang length equals 1/2 the gable end truss spacing, or 12”. For rake overhang lengths greater than 12”, the procedures outlined below must be used.

**Required Actions**

Manually apply additional load to the truss top chord for Live Load, Dead Load, Snow Load, and Wind Loads as required per the design loading, or adjust the truss on-center spacing, as shown in the table below.

![](/images/csdirector-cstruss/resources/images/cr-maxrakeoverhangtable.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** This applies only to gable trusses that are spaced exactly 24” away from the first common truss. For other spacings and configurations, contact Simpson Engineering to assist in determining load requirements.

#### **Example of Manual Truss Loading**

The following example illustrates how to manually load a truss.

A gable truss spaced 2' on-center has a 2' rake overhang and design loading of :

- TCLL= 20 PSF
- TCDL= 10 PSF
- Roof Snow = 45 PSF


To determine how much additional load is needed:

1. Calculate the number of *Feet of Additional Load* to add to the gable truss:


| *Feet of Additional Load = 2 x Rake Overhang Length – Gable Spacing* |
|  --- |
| Using the values from the example truss, *Feet of Additional Load* is:  2 x 2' - 2' = 2' |


1. Using the *Feet of Additional Load* from Step 1, calculate the amount of additional load for each load type to add to the gable truss top chord:


a. *Total Roof Live* = *TCLL* Feet of Additional Load = 20 PSF * 2 FT =* **40 PLF additional TCLL** b. *Total Dead Load* = *TCDL* Feet of Additional Load = 10 PSF * 2 FT* = **20 PLF additional TCDL** c. *Total Snow Load* = *Roof Snow Load * Feet of Additional Load = 45 PSF * 2 FT* = **90 PLF additional Snow Load**

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** For additional snow loading, roof snow load rather than ground snow load must be applied. To determine the roof snow load, navigate to Load Template manager > Snow Load and enter the Specified Roof Snow Load, psf.

![](/images/csdirector-cstruss/resources/images/cr-specifiedroofsnowload.png)

d. Additional steps are required to determine the amount of wind load to add to the truss:

i. Navigate to **Component Loading > Distributed Load**.

ii. For **Total Load** enter the total load for Roof Live Load + Dead Load or Snow Load + Dead Load (whichever is greater). For this example, Snow Load + Dead Load = **110 PLF** > Roof Live Load + Dead Load= 60 PLF.

![](/images/csdirector-cstruss/resources/images/cr-calculatewindload.png)

When you press **Tab** to enter the load, it is factored into the corresponding load types based on the design criteria of the truss, including wind load.

iii. Note the -18.7 plf of wind load generated by the application; this is the required additional wind load for the truss.

1. Add the total loads determined above to the gable end top chord in the **Distributed Load** dialog. As illustrated by the example, the required additional loads are as follows: Roof Live = 40, Dead Load = 20, Snow Load = 90, and Wind load = -18.8


a. Input additional loads for the corresponding load types in both the **Start** and **End** fields to apply those loads.

![](/images/csdirector-cstruss/resources/images/cr-additionalloads.png)

1. Adjust the additional load as needed for other rake overhang dimensions.


**Related Topics**

[Create Distributed Loads](/csdirector-cstruss/help-center/design-view/loading/distributed-load)

[Load Template Manager - Snow Load](/csdirector-cstruss/help-center/design-view/loading/snow-load)