# Properly Load Hip Girders Using Hip Girder Macro

**Description**

When using the Hip Girder loading macro to apply loads to a hip girder and any secondary girders, select the appropriate settings for Single Girder or Multi-Girder, Corner Type, and End Jacks.

**Design Practices**

Loading for Hip Girders is defined on the Hip Girder Loading dialog. Go to Truss Design View > click Component button > click Hip Girder button.

![](/images/csdirector-cstruss/resources/images/cr-comploading-rs.png)

The Hip Girder Loading dialog displays.

**1. Single Girder or Multi-Girder settings**

![](/images/csdirector-cstruss/resources/images/cr-hipload-girders.png)

a. Hip Girder (no Secondary) - Used only on primary hip girders if **either** of the following conditions exist:

- The primary hip girder is the only hip girder in the hip set. This is most common with step-down style hip sets where corner rafters/girders and end jacks do not have extended top chords,   ![](/images/csdirector-cstruss/resources/images/cr-primaryhipgirder.jpg)


or

- The corner rafters/girders and end jacks have extended top chords, but the flat top chord of the hip truss directly behind the primary hip girder steps up to carry the loads from the corner rafter/girder and end jacks top chord extensions.  ![](/images/csdirector-cstruss/resources/images/cr-hipgirder-cornerrafter.jpg)


b. Hip Girder (with Secondary) - Used only on primary girders when **both** of the following conditions exist:

- The corner rafters/girders and end jacks have extended top chords (they extend beyond the primary hip girder); **and**
- The flat top chord of the hip truss directly behind the primary hip girder does not step up to carry the loads from the corner rafter/girder and end jack top chord extensions.  ![](/images/csdirector-cstruss/resources/images/cr-hipgirderwithsecondary-782x289.jpg)


c. Secondary Girder - Used only on secondary girders when **both** of the following cases exist:

- The corner rafters/girders and end jacks have extended top chords (they extend beyond the primary hip girder, and either of the following conditions exists:
- The hip trusses step up every third truss to carry the loads from the corner rafter/girder and end jack top chord extensions; **or** the hip trusses step up every other truss and the top chord total load (TC live (or snow) plus dead) is greater than 50 psf.  ![](/images/csdirector-cstruss/resources/images/cr-secondarygirders-618x257.jpg)


**2. Corner type**

![](/images/csdirector-cstruss/resources/images/cr-hipload-corners.png)

a. Rafter - Used only when the corner set is supported by a corner rafter.

![](/images/csdirector-cstruss/resources/images/cr-cornertype-rafter-708x349.jpg)

b. Truss TC - Used only when the corner set is supported by a corner girder truss, and the corner girder is closed (end vertical used, with only a top chord support).

![](/images/csdirector-cstruss/resources/images/cr-cornertype-trusstc-701x309.jpg)

c. Truss BC - Used only when the corner set is supported by a corner girder truss, and the corner girder is closed (end vertical used, with only a bottom chord support).

![](/images/csdirector-cstruss/resources/images/cr-cornertype-trussbc-760x281.jpg)

d. Truss TC & BC (Future enhancement, implemented in 2021.5) - Used only when the corner set is supported by a corner girder truss rather than a rafter, and the corner girder is open (no end vertical, with top chord and bottom chord supports at the right end).

![](/images/csdirector-cstruss/resources/images/cr-cornertype-trusstc-bc.png-720x319.jpg)

**3. End Jacks**

![](/images/csdirector-cstruss/resources/images/cr-hipload-jacks.png)

a. JackOpen - Used only when the end jacks are open (no end vertical) and have no webs. The top chord could be extended beyond the primary hip girder to be supported by the hip trusses behind it, or could stop at the primary hip girder.

![](/images/csdirector-cstruss/resources/images/cr-endjacks-jackopen.jpg)

b. JackEndVert - Used only when the end jacks are closed (with end vertical). The top chord could be extended beyond the primary hip girder to be supported by the hip trusses behind it, or could stop at the primary hip girder.

![](/images/csdirector-cstruss/resources/images/cr-endjacks-jackendvert.jpg)

c. JackMidTC - Used only when the end jacks are open (no end vertical) and have a diagonal web going from the right end of the bottom chord to inside the truss profile. The top chord could be extended beyond the primary hip girder to be supported by the hip trusses behind it, or could stop at the primary hip girder.

![](/images/csdirector-cstruss/resources/images/cr-endjacks-jackmidtc.jpg)

**Additional Resources**

Create Hip Girder Loads

Hip Girder Loading Settings