# Purlins / Sheathing & Corresponding Dead Loads

**Description**

There are two types of bracing -- purlins and sheathing. Ensure that the bracing type selected is appropriate for the truss, and that the design dead loads correspond to the bracing method.

**Design Practices**

**When to Use Purlins**

- A truss with spacing > 30" o.c. and/or bottom chord dead load less than 4 psf should be designed with purlins, in most cases.
- A truss that was not designed to support a sheathing dead load should be designed with purlins. Alternatively, the dead load should be revised to reflect the weight of the sheathing. Typically, bottom chord or top chord dead load should be greater than 4 psf to reflect the proper weight of the sheathing. Note that you must include the weight of the truss in the dead loads entered. The weight of the truss is not automatically applied by Truss Studio.
- A truss using spacing greater than the typical allowable span rating for sheathing should be designed with purlins.


**When to Use Sheathing**

- If truss spacing is larger than 30” o.c. and sheathing is applied using intermediate framing, such as ladder blocking between the trusses, the sheathing bracing method is appropriate.


Calculating Dead Loads

![](/images/csdirector-cstruss/transparent.gif)View the guidelines to estimate the approximate dead loads (DL) for chord sheathing/purlin bracing.

• Plywood/OSB at 0.4 psf per 1/8-inch of thickness.

Example: ½-inch plywood = 0.4 x (1/2 / 1/8) = 1.6 psf DL

• Gypsum board at 0.5 psf per 1/8-inch of thickness.

Example: ½-inch gypsum board = 0.5 x (1/2 / 1/8) = 2.0 psf

• Purlin Dead Load* = 0.42 x Purlin Depth (largest dimension in inches) divided by the Purlin Spacing (ft) along chords

Example: 2x4 Purlins at 2-ft oc = 0.42 x 3.5 / 2 = 0.7 psf

Example: 2x4 Purlins at 8-ft oc = 0.42 x 3.5 / 8 = 0.2 psf

*** Purlin Dead Load Calculation is based on:**

![](/images/csdirector-cstruss/resources/images/cr-purlindeadload-calcs-793x125.png)

**Required Actions**

Verify the following:

- Design dead loads for the bottom chord and the top chord reflect the bracing method selected, purlins or sheathing.
  - For sheathing, ensure that the bottom chord and/or top chord dead load reflect the correct weight of the sheathing material (typically, >4 psf).
  - For sheathing, ensure that truss spacing is less than the allowable span rating of the sheathing used to brace the chord.


**Additional Resources**

Purlins

SBCA Load Guide (you must provide your name and email to access this resource)