# Drag Truss Design - Shearwall & Drag Truss Anchorage Locations

**Description**

Shearwall and drag truss anchorage locations are critical to the proper design of drag trusses. Ensure that drag truss anchorage locations and any shearwalls specified by the Construction Documents have been input into the Drag Load dialog to ensure the proper design of the drag truss.

**Design Practices**

![](/images/csdirector-cstruss/resources/images/video-icon-43x44.png) Watch video

When a drag load is input for a truss and no shearwalls are entered from the Drag Load dialog, the program designs the truss so that it can be anchored to resist the applied drag load at any bearing location. Special attention should be given to drop leg bearing locations. Anchorage of the drag truss at the bearing for a drop leg condition is not a common detail and should be avoided unless required by the EOR.

When a drag load is input for a truss and no shearwalls are entered on the Drag Load dialog and the truss has continuous bearing or partial continuous bearing, the program designs the truss so that it is anchored to resist the applied drag load ONLY at the center point of the continuous bearing or the center point of the partially continuous bearing. This is also not a common detailing practice. Drag trusses are generally attached at an interval to shearwalls below.

When a drag load is input for a truss and shearwalls are entered from the Drag Load dialog, the program designs the truss to be anchored continuously to resist the applied drag load to the top of the shearwall which is common for most lateral force resisting system designs.

**Required Actions**

In all cases, it is best practice to input all shearwall locations that are specified by the Construction Documents and their extents into the design of the drag trusses above them. This ensures that the drag truss is designed properly based on the location of its anchorage to the shearwalls.

If the drag load is required to be resisted at a location other than a bearing, and that location is not a shearwall (such as the case of a horizontal strap), input a 12” shearwall at the desired location to model the connection. This ensures that the drag truss is designed properly for the anchorage method. Verify that drag trusses with drop legs have a shearwall or anchorage point specified at another location along the truss.

**Example: Drop Leg Bearing**

![](/images/csdirector-cstruss/resources/images/dropleg-sw-examples.jpg)

When a drag truss has a continuous bearing or partial continuous bearing, input a shearwall that extends the full length of the continuous bearing or partially continuous bearing, or enter specified shearwall segments and their extents into the Drag Load dialog.

**Example: Partial Continuous Bearing**

![](/images/csdirector-cstruss/resources/images/cr-partcont-bear-sw-examples.jpg)

In all cases, shearwalls should be input for continuous or partially continuous bearings unless otherwise specified by the Construction Documents. It is typical for a shearwall to exist that is not a bearing wall, but it is not typical for a bearing wall to exist that is not also a shearwall.

**Example: Continuous Bearing**

![](/images/csdirector-cstruss/resources/images/cr-contbearing-sw-examples.jpg)