# Verify Roof/Floor Loading Templates

**Description**

Trusses may be designed with loading templates that are inappropriate for their intended application. For example, a roof truss might have a floor loading template applied, or a floor truss might have a roof loading template applied.

**Design Practices**

When designing floor or roof trusses, ensure the loading template used corresponds to the intended roof and/or floor application.

**Required Actions**

When creating a new template, it is recommended to include "Roof" or "Floor" in the template name.

![](/images/csdirector-cstruss/resources/images/cr-rooffloortemplatename-579x102.png)

**Roof Trusses**

The following best practices should be considered when designing a roof truss:

- Whether you are designing with lumber in a 2xW or Wx2 orientation, verify you have applied the correct load template to accommodate roof loading.
- Generally, roof trusses:
  - Have a pitch greater than or equal to 0.25/12.
  - Have a live load duration greater than 1.00. However, there may be jurisdictions in snow load areas that require a snow load duration (and in some cases, a live load duration) of 1.00.
  - Have wind load applied
  - Have specific deflection criteria.


![](/images/csdirector-cstruss/resources/images/cr-roof-loading-example.jpg)

**Floor Trusses**

The following best practices should be considered when designing a floor truss:

- Whether you are designing with lumber in a 2xW or Wx2 orientation, verify you have applied the correct load template to accommodate floor loading.
- Generally, floor trusses have a pitch less than or equal to 0.25/12.
- Generally, floor trusses do not have wind load applied. However, there are scenarios, such as a lower-level roof system, deck or balcony, where floor trusses are exposed to wind.
- Floor trusses must always have a live load duration of 1.00.
- Floor trusses must always have a minimum L/360 Live Load and L/240 Total Load deflection criteria. In some cases, construction documents require a more stringent deflection criteria such as L/480 Live Load and L/360 Total Load.


![](/images/csdirector-cstruss/resources/images/cr-floor-loading-example.jpg)

**Additional Resources**

Load Template Manager