# Enable/Disable Connections

**Purpose**

Easily disable connections without analyzing trusses

Note that you can also disable connections by turning the Enable Connection check box off on the Modify Connection tab of the Connection Dialog. The procedure described in this topic provides a way to disable connections without analyzing trusses.

**Prerequisites**

An existing layout

**Steps**

![](/images/csdirector-cstruss/resources/images/video-icon-43x44.png) Watch video

1. Select one or more connectivity indicators to enable or disable.


The selected indicators are highlighted

1. From the **Truss Operations** menu, select **Disable/Enable Connections** or click ![](/images/csdirector-cstruss/resources/images/button.png).


Any enabled connections are disabled and any disabled connections are enabled. They are displayed in the appropriate color on the layout. Different colors indicate different truss states:

• A red symbol indicates the connection is enabled and affected trusses are unanalyzed

• A blue symbol indicates the connection is enabled and affected trusses are analyzed

• A grey symbol indicates the connection is disabled

If any of the selected connections have a top and bottom connectivity indicator located at the same location (as indicated by ![](/images/csdirector-cstruss/resources/images/ts-connectivityindicatorsamelocation.png)), the **Connection Location** window displays.

1. Select the appropriate connection location and click **OK**.


The connection status of the selected connection is enabled or disabled.

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png)**Notes**

- Disabling a connection removes the bearing at that location on the child truss.
- Enabling a connection adds a bearing at that location on the child truss.
- All trusses in Truss Studio require at least two bearings. If a connection is disabled and the child truss has only one other bearing, an additional bearing is added to the end of the truss on the opposite end as the existing bearing; this may mean that a bearing is added back at the disabled connection.
- The bearing is not removed when the connection is disabled if the child truss has a single continuous bearing (i.e., gable truss). However, the connection is still disabled and load transfer will not occur at that location.
- Adding and removing bearings when enabling/disabling connections will not unlock the truss.


**Related Topics**

[Display Control settings](/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/display-control-settings) (to define color palette for loads and hangers)

[Select Connectors in Layout](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/select-connectors-layout)

[Select a Connector Not in Inventory](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/select-connection-not-in-inventory)

[Select Multi-truss Connectors](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/select-multi-truss-connector)

[Manually Create a Connection](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/manually-create-connection)