# Select Connectors in Layout

**Purpose**

To select existing connectors in Layout for truss-to-truss connections where a girder truss independently carries one or more child trusses

**Prerequisites**

A layout with truss-to-truss connections

**Steps**

1. On the **Truss Operations** menu, select **Manual Connector Selection** or click ![](/images/csdirector-cstruss/resources/images/ts-manualconnectorselection.png)on the Truss Operations toolbar.


The following prompt displays in the caption bar:

Select a connectivity indicator to create a connector. Esc or right-click to exit command.

1. Select a connectivity indicator.


The selected connection is highlighted, as are any other connections with the same girder and child trusses. The **Connection Details** window displays.

![](/images/csdirector-cstruss/resources/images/connection-details-306x167.jpg)  The color of the indicator may vary, depending on the status of the connection.

![](/images/csdirector-cstruss/transparent.gif)Learn more about connections and the Connectivity Indicator

- If the selected connectivity indicator has both a top and bottom connection, the Top and Bottom options are enabled (Bottom option is selected by default).
- If the selected indicator has either a top or bottom connection (not both), the corresponding option is selected.
- Separate connectors can be used on the top and bottom connections
- If the selected connection has multiple child trusses with the same label that connect to the same girder truss, all identical connections are highlighted. When this occurs, the Selected Connection Only box is enabled. but not selected; the option may then be selected.
- When the Selected Connection Only option is selected, only the connection that was originally selected will be highlighted, after you click OK. The selected connector is applied only to that connection. This does not impact consolidation (truss labels) if only a single connector is specified. Trusses with the same labels can use different connectors.\
- If there is a single connection only (one truss with a unique label hanging into a girder) the Selected Connection Only option is selected and the check box is disabled.


1. Select the desired options in the **Connection Details** window and click **Add Connectors**. There are several options that may display, depending on the analysis state of the trusses:


- If the trusses that make up the connection have not been analyzed (both the girder and child truss) the Analyze Trusses window displays. Click **Yes** to complete the analysis. If you select **No**, the connection indicators are deselected.


![](/images/csdirector-cstruss/resources/images/analyzefirst-275x144.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** The analysis honors the Transfer Loads Automatically setting (under Layout Settings > Load Transfer). If Transfer Loads Automatically is enabled, selected load transfer point loads will be created on analysis. If this option is not enabled, the analysis will run without transferring loads. If load transfer point loads were previously transferred, the following window is displayed.

![](/images/csdirector-cstruss/resources/images/load-transfer-dialog-397x149.png)

- If the trusses have been analyzed and are failing analysis, the **Failing Analysis** window displays.


![](/images/csdirector-cstruss/resources/images/notpassinganalysisdialog-323x122-396x149.png)

- If both the child and girder trusses have been previously analyzed and have passed analysis, Truss Studio generates a list of possible solutions. That list is filtered down to a list of solutions with only those connectors contained in the project inventory. This list is displayed on the **My Inventory** tab. If no solutions are available and contained in inventory, **No Solutions** is displayed.


![](/images/csdirector-cstruss/resources/images/my-inventory-431x258.png)

- The list can be further filtered by selecting one of the options in the **Style** drop down list.


![](/images/csdirector-cstruss/resources/images/my-inventory-solutions-with-style-dropdown-420x254.jpg)

- The Connections section reflects the selections made in the Connection Details window in step 1. The Connections section is not editable and is shown here only for informational purposes.
- The Load, Uplift, and Plies boxes are populated with the reaction information from the child truss.
- The Show Catalog Page and Add to Elevation buttons are disabled until one of the items on the list is selected. Once a connector is selected on the list and the Show Catalog Page button is selected, a PDF of the catalog page with the selected connector displays.
- If this window is re-opened after a hanger is specified, it opens to the tab where the connector was selected and the previously selected connector is highlighted.
- Special Order hangers display on the list in red.


![](/images/csdirector-cstruss/resources/images/ts-specialorderhangerlist.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note:** The **Connection Info** tab displays the design parameters used in hanger selection, ensuring clarity and confidence in your hanger designs by making connector data more transparent. This text is informational only and cannot be edited, except by modifying the components that are being connected.

![](/images/csdirector-cstruss/resources/images/ts-connectioninfotab-877x534.png)

1. Select a connector from the drop down list.


The selected connector is highlighted on the list and **Show Catalog Page** and **Add to Elevation** are enabled.

1. Click **Add to Elevation**.


The window closes and all trusses of the same type are populated with the same connector; one or more hanger symbols displays on the layout. In addition, a Connector Schedule is created for your first connecter selection.

Connector information is also saved to **Miscellaneous** items in Director, as well as to the **Elevation**, with the quantity of the number of connections that were highlighted in step 1 (the quantity of identical trusses that are being carried by the girder).

- If other connectors were previously selected and a connector schedule has already been created, the newly selected hanger is added to the schedule.
- Each connector is labeled with a letter with a square or circle around it on the layout. Circle represents a top chord connection and square represents a bottom chord connection.
- Each hanger in the schedule corresponds to a symbol on the layout.
- You can resize or move the schedule using the Drag Dim/Label command.


![](/images/csdirector-cstruss/resources/images/hanger-schedule-with-color-628x468.jpg)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png)**Notes:**

- If the child or girder truss geometry or reactions change, the previously selected connector is checked against the new condition. If the existing connector still works, it remains assigned to that connection. If the connector fails, it is removed. This means that the hanger symbol is removed as well as the connector in the Director Elevation and Connector schedule.
- If an additional connector is selected and added to the elevation, Director automatically updates to reflect the hangers that were selected on the layout. This may mean that the quantities of connectors in Director may change, or it may mean that a hanger SKU is removed and the new one added. The change is also reflected on the hanger schedule.
- Selected connectors remain when the layout is mirrored, rotated, or copied unless mirroring a skewed connection. Mirrored skewed connectors must also be mirrored (i.e., changed from rights to lefts).
- Once a connector is specified using the steps described here, a hanger symbol displays. The hanger symbol is color coded to indicate how the connector was specified. The default colors can be defined in the [Color Settings](/csdirector-cstruss/help-center/design-view/color-settings) on the EnvData page.
- 3D hangers display on the layout. Generic 3D hangers display if there is not a supporting .stl file.


![](/images/csdirector-cstruss/resources/images/ts-3dhanger-example1-538x372.png)

**Related Topics**

- [Display Control settings](/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/display-control-settings) (to define color palette for loads and hangers)
- [Select a Connector Not in Inventory](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/select-connection-not-in-inventory)
- [Select Multi-truss Connectors](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/select-multi-truss-connector)
- [Manually Create a Connection](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/manually-create-connection)
- [Enable/Disable Connections](/csdirector-cstruss/help-center/layout-view/connector-selection-overview/enable-disable-connections)