# Report Reactions on Layout

**Purpose**

Report/display upward and downward reactions on layout that exceed defined limits established in presets.

**Steps**

1. Naviagte to **Env Data** > **Layout Settings** > **Load Transfer** and define the following settings:
Minimum Downward Reaction to Display, -1 to Disable   Minimum Upward Reaction to Display, -1 to Disable


For this example:

- **Minimum Downward Reaction to Display, -1 to Disable** is set to 1500
- **Minimum Upward Reaction to Display, -1 to Disable** is set to 100


1. Analyze the trusses.


Reactions that fall outside of the defined parameters are displayed. Upward reactions display as a negative number; downward reactions display as a positive number.

![](/images/csdirector-cstruss/resources/images/ts-trussreactionsonlayout-869x656.png)

![](/images/csdirector-cstruss/resources/images/note-onlinehelp.png) **Note**: Load transfers are updated when analyzing a truss or when editing a truss, depending on the setting defined in Env Data > Layout Settings > Load Transfer > Update Load Transfers. If you choose to update load transfers whenever you edit a truss, this may have a negative impact on performance.

1. To define or change the font used for reactions on the layout, open the EnvData window and click **Font Settings**.


The **Font Settings** dialog displays.

1. Select a font style, size, and color.


![](/images/csdirector-cstruss/resources/images/ts-trussreactionfont.png)

1. To drag the reaction label to another location on the layout, use the Drag Annotations ![](/images/csdirector-cstruss/resources/images/ts-dragannotationsicon.png) command.


A leader line is created and moves with the label.

![](/images/csdirector-cstruss/resources/images/ts-dragreactionlabel.png)

The reaction label properties can also be viewed/edited in the Preview Pane.

![](/images/csdirector-cstruss/resources/images/ts-reactionspropertypane-1011x605.png)