# Update Loads on Disconnected Trusses/Rafters

**Purpose**

This feature is useful for editing loads on trusses/rafters without saving them to Director. Note that load transfer does not happen on disconnected trusses; this workflow demonstrates how to transfer loads on trusses/rafters that you do not want to save to Director.

**Steps**

In this example, there is a rafter and ridge board which transfer loads to the adjacent truss. The load on the rafters will be edited.

![](/images/csdirector-cstruss/resources/images/ts-disconnectrafterridgeloadtrans.png)

1. Identify loads on a truss by opening it in Design view.


![](/images/csdirector-cstruss/resources/images/ts-disconnectloadsindesign-1040x342.png)

In this example, truss T07, which is adjacent to the two rafters, has a load of 303#.

1. Select all the T07 trusses.
2. Click **Component Loading** > **Load Transfer** to open the **Load Transfer Point Load** dialog.


![](/images/csdirector-cstruss/resources/images/ts-disconnectcopiedload.gif)

1. Make a copy of the load and click **OK** to close the dialogs.
2. Return to the layout and select the two rafters.


![](/images/csdirector-cstruss/resources/images/ts-disconnectselectrafters-360x400.png)

1. In the **Properties** pane, select **Yes** under **Truss Disconnect** to disconnect the selected rafters.


![](/images/csdirector-cstruss/resources/images/ts-reafterdisconnectproppane.gif)

The rafter labels turn red to indicate that they are disconnected.

![](/images/csdirector-cstruss/resources/images/ts-disconnect-redlabels-802x346.png)

In order to change loads on the rafters/trusses, you must first reconnect them.

1. Select rafter R2 and reconnect using the Properties Pane.
2. Go to **Component Loading** > **Point Load** and make edits. In this example, points loads were edited, as shown below.


![](/images/csdirector-cstruss/resources/images/ts-disconnectrafterpointloadedits.gif)

1. Save load changes.
2. Return to the layout and reanalyze the truss.
3. Click **Yes** at the following prompt to update the point load:


![](/images/csdirector-cstruss/resources/images/ts-updatedloadsprompt.gif)

1. View the updated loads in Design view.


![](/images/csdirector-cstruss/resources/images/ts-disconnectaddedpointload.gif)

1. Return to the Point Load dialog and delete the copy of the loads you created in Step x above.
2. Copy the newly created load combination.


![](/images/csdirector-cstruss/resources/images/ts-disconnectrecopyupdatedload.png)

1. Select the two rafters and disconnect them in the Properties Pane.
2. Reanalyze truss and respond Yes to save updated loads.
3. View updated loads in layout.


![](/images/csdirector-cstruss/resources/images/ts-disconnectfinalloads.gif)

**Related Topics**

[Disconnect Trusses from Layout](/csdirector-cstruss/help-center/layout-view/disconnect-trusses-from-layout)