# Simpson Strong-Tie® Component Solutions™ Truss Studio 2025.7

## Features & Enhancements

### Truss Studio Design

You can now designate a parapet strut to be field-applied. This feature allows the strut to be used for analysis, but not included in lumber production (no cutting, no bidding) and is shown on the truss drawing as a double dashed-line (edges of where a physical member is assumed to be placed) with an accompanying installation note.

Use the Add Board dialog to select Field Applied; the field-applied status is also reflected in the Properties pane. See [Add Board in the Operations menu](/csdirector-cstruss/help-center/truss-studio-online-help/menus-toolbars/operations-menu).

![Field-applied board example](/assets/ts_fieldapplied-board-example_529x488.b943def1825049d7f73c1b2e9e34dbcc03deaaa999b996b49941d4166d962ff6.7d18c97d.png)

![Field-applied board in the Properties pane](/assets/ts_field-applied-properties.9a9797cc51755a2fb6ed857f2bac5c87f18f26e7c9cf03862d8ac1bcaeef975b.7d18c97d.png)

New options were added to address overstressed webs. The Env Data setting for **Path to follow to fix web overstress** now includes the following additional options:

- **BG (Brace, Grade/species):** The application attempts bracing first, then upgrading grade/species, but never upsizing lumber.
- **GB (Grade/species, Brace):** The application attempts upgrading the grade/species first, then adding bracing, but never upsizing lumber.
- **G (Grade/species only):** The application attempts upgrading grade/species, but never upsizes lumber and never adds bracing.


These additional options benefit customers (especially HUD customers) since they are not forced to have lumber size rules applied to trusses with non-typical input lumber sizes. Access these settings at EnvData > Analysis > Bracing Data > Path to follow to fix web overstress; Brace/Grade/Size.

For special HUD sizes (set to True in EnvData) no upgrading will be done for either size or grade, and setting this option to G means no bracing will be attempted either, resulting in a web that fails if it doesn't work with the specified special size and selected grade. You must manually upgrade as needed, then reset the special size as needed, in order to obtain a passing web.

The EnvData > OneTrussControls > WallTopPlateMaterial-USA setting now includes a USER option. When this option is selected, PSI is set to 999 by default in the Bearings dialog. Setting this as a default in EnvData streamlines your work process. You can still manually edit the PSI on the Bearings dialog. This option allows bearings to be designed based on truss material only, leaving the Engineer of Record (EOR) the flexibility to design walls.

![Wall top plate material USER setting](/assets/ts_bearing_walltoppiece-user_999.474d32ec7ba1e1aa6dc9c2ca08b5cacfb9c64562f44b08250938ce7ac602e905.7d18c97d.png)

For raised heel trusses with fire-treated overhangs, the near-end splice joint automatically receives a splice block and larger plate to help with the manufacturing of trusses with roller presses. This option automatically inserts a splice block for raised heel (stub-end) trusses when a splice joint is present. You can still manually insert a splice block for other heel conditions, such as 4-sided wedge heels.

This feature improves the speed and accuracy of truss design involving fire-treated overhangs by reducing manual intervention and ensuring compliance with structural requirements.

![Splice blocks for fire-treated raised heel trusses](/assets/ts_firetreatedraisedheel_spliceblocks_810x376.4f6a69517002380b3e44a9a9fbe0e907c5a08f843dc6223127f16c9a2fe2ad47.7d18c97d.png)

Truss Studio now calculates and reports in Properties the area of the truss face and the volume the truss represents (truss face times on-center spacing). Note that the face area does not include overhangs or extensions.

![Truss face area and volume properties](/assets/ts_trussface_volume_1180x258.5b7e65a01eaf1e91b5c2ffd0f5beff95c231b6e4357384e453106cb3eb1ff455.7d18c97d.png)

- A TDD reporting issue with ASCE7-22 snow loads and the Snow Load dialog has been resolved.
- An issue with ASCE7-22 snow loads using the minimum snow instead of the required snow has been fixed.
- Gable rake overhang and wind exposure notes no longer appear on Wx2 trusses when the wind load setting is disabled.
- Cantilever floors with no ribbons maintain end vertical(s) at the end.
- California 2025 building codes (CBC-2025 and CRC-2025) are now available in Load Template Manager.
- Oregon OSSC-2022 building code is now available in Load Template Manager.


#### Resolved Issues

- Non-structural plates no longer overlap other non-structural plates.
- Previously, when the material catalog contained stock lengths greater than the Geometry > AutoSplice > BC/TC Max Length setting, and you attempted to splice a chord where the splice occurred at greater than the length specified in the setting, a warning displayed, regardless of whether the length needed was in stock; this has been resolved.
- An issue with floor truss composite analysis using extra plates has been resolved.


### Truss Studio Layout

- The US Connector Selector DLL was updated to version 2025.5.29, for offline use.


#### Resolved Issues

- Load transfer has been improved in cases where trusses with manual loads are moved in layout.
- Previously, a load transfer still applied to a truss after creating and then disabling the connection; this has been resolved.
- Hanger selection has been improved in cases with bearing blocks at truss ends with sloped bottom cut.
- Selection of planes when reprofiling trusses has been improved to better support the selection of horizontal planes.
- The top chord of corner girder truss is now extended to the hip peak when using double bevels.