# Recommended EnvData Settings

The following table provides recommended default EnvData settings when setting up Truss Studio.

| EnvData Menu | Preset Setting | Default Value | Recommended Value | Country/Region/Note |
|  --- | --- | --- | --- | --- |
| Load Template Manager | Valley/Cap BCDL | Typical | 1 | US & CAN |
| Edit Fastener Settings | 2, 3, 4, 5, 6 Ply | Blank | As required | US & CAN |
| Edit Fastener Settings | Alternate Fasteners and Triggers | Blank | As required | US & CAN |
| Dialogs > Attic | Width of room | 10 | 5 | Typ. for Southwest US |
| Dialogs > Attic | Height of room | 8 | 0 | Typ. for Southwest US |
| Dialogs > Attic | Apply Attic Load | True | False | Typ. for Southwest US |
| Dialogs > Attic | Apply Mech Load | False | True | Typ. for Southwest US |
| Dialogs > Attic | Room Floor Option | None | Stacked Chord | Typ. for Southwest US |
| Dialogs > Cosmetic Filler | Cosmetic Filler - Stud Spacing | 6-0-0 | 4-0-0 |  |
| Dialogs > Gable | Stud spacing | 2 | 1-4-0 | Typ. for Southwest US |
| Dialogs > Gable | Min stud length | 1-0-0 | 0-6-0 |  |
| Dialogs > HipGirderLoading | Corner Type | Truss BC | Rafter | Typ. for Southwest US |
| Dialogs > MechLoad | Mech Unit Load (per truss) | 25 | 75 | Typ. for Southwest US |
| Dialogs > MechLoad | Use two point loads? | True | False | Typ. for Southwest US |
| Dialogs > MechLoad | Width | 4-0-0 | 5-0-0 | Typ. for Southwest US |
| Dialogs > Polyfill | Spacing | 2-0-0 | 1-4-0 | Typ. for Southwest US |
| LayoutSettings > MfgControls | Lay-in gable fit tolerance | 0 | 00-04 |  |
| LayoutSettings > WallsAndPlanes | OH: How measured? | OutPnt | As required |  |
| LayoutSettings > WallsAndPlanes | OH: End Cut | Plumb | As required |  |
| LayoutSettings > WallsAndPlanes | Attach Roof Plane to wall | True | False | User preference |
| LayoutSettings > Beams | Beam Height | 308 | 9.5 or 11.875 | User preference |
| LayoutSettings > Labels | Default Label Format | Plan-Elevation_TrussID | Preset Labels |  |
| LayoutSettings > LumberSizeData | Girder truss BC | 0-3-8 | 0-5-8 |  |
| LayoutSettings > Load Transfer | Update Load Transfers | Any Edit | Only When Analyzing |  |
| LayoutSettings > Load Transfer | Minimum Downward Reaction to Display, -1 to Disable | -1 | 3000 | User preference |
| LayoutSettings > Load Transfer | Minimum Upward Reaction to Display, -1 to Disable | -1 | 1000 | User preference |
| LayoutSettings > Hipset | Style of Hip System | Step Down | California | Typ. for Southwest US |
| LayoutSettings > Hipset | Step up | Every Truss | Every 2nd | Typ. for Southwest US |
| LayoutSettings > Hipset | Style of Corner Girder | Truss | Stacked Rafter | Typ. for Southwest US |
| LayoutSettings > Hipset | Hip Girder setback | 6-0-0 | 8-0-0 | Typ. for Southwest US |
| LayoutSettings > Hipset | Max span jack with no end vert | 7-0-0 | 8-0-0 | Typ. for Southwest US |
| LayoutSettings > Hipset | Jack TC bearing type | Hanger | Toenail | Typ. for Southwest US |
| LayoutSettings > Hipset | Jack BC bearing type | Hanger | Toenail | Typ. for Southwest US |
| LayoutSettings > Hipset | Bevel - Corner | None | Double | Typ. for Southwest US |
| LayoutSettings > Hipset | Bevel - End Jacks | None | Double | Typ. for Southwest US |
| LayoutSettings > Hipset | Bevel - Side Jacks | None | Double | Typ. for Southwest US |
| Layout Settings > ValleySet | Valley Stud Spacing | 6-0-0 | 4-0-0 | Requirement for Compoenent Review |
| Layout Settings > PiggyBack | PiggyBack Stud Spacing | 6-0-0 | 4-0-0 | Requirement for Compoenent Review |
| Geometry > Geom_2xW > PanelLengths_2xW | Design TC panel length 2x4 | 6-0-0 | 8-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design TC panel length 2x6 | 6-0-0 | 8-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design TC panel length 2x8 | 6-0-0 | 8-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design TC panel length 2x10 | 6-0-0 | 8-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design TC panel length 2x12 | 6-0-0 | 8-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design BC panel length 2x4 | 8-0-0 | 10-0-0 |  |
| Geometry > Geom_2xW > PanelLengths_2xW | Design BC panel length 2x6 | 8-0-0 | 10-0-0 |  |
| Geometry > PanelLengths_2xW | Design End Jack TC panel length 2x4 | 6-0-0 | 8-0-0 | Typ. for Southwest US |
| Geometry > Geom_2xW > Web_2xW | Web from bottom vertical at hip drop shoulder joints | False | True | Typ. for Southwest US |
| Geometry > Geom_Wx2 > PanelLengths_Wx2 > War/Fan | Std & Max panel length | 2-0-0 | 2-6-0 |  |
| Geometry > Geometry Controls | Maximum scarf length for web cuts | 1-0-0 | 0-7-0 | US & CAN |
| Geometry > Geometry Controls | Vertical under sloped member at Hip joint | True | False | US & CAN |
| Geometry > Geom_CantileverBearings | Vertical webs at cantilever bearings | False | True |  |
| Geometry > AutoSplice | Minimum board length | 4-0-0 | 8-0-0 |  |
| Analysis > OverallControls | Allow excessive deflection condition to trigger update | False | True | US & CAN |
| Plating > BrgBlockPlateControls_2xW | Max block length before Tie Plate required | 1-0-0 | 600 | US & CAN / Requirement for Component Review |
| Plating > BrgBlockPlateControls_Wx2 | Max block length before tie plate required | 1-0-0 | 600 | US & CAN / Requirement for Component Review |
| OneTrussControls | Wall Top Plate Material - USA | SPF | DFL | Typ. for Southwest US |
| UserInterface | Auto-save interval (seconds), or 0 to disable | 120 | 600 to 900 |  |
| UserInterface | Single Select (new selection clears previous selections) | False | True | US & CAN |
| UserInterface | Layout - On-screen Line Thickness | 10 | 20 |  |
| UserInterface | Clear selected objects after updating properties | True | False |  |
| UserInterface | Show analysis output automatically | True | False | User preference |
| UserInerface > Graphics | Anti-Aliasing | None | X2 or X4 |  |