{"templateId":"markdown","sharedDataIds":{"sidebar":"sidebar-csdirector-cstruss/help-center/sidebars.yaml"},"props":{"metadata":{"markdoc":{"tagList":[]},"type":"markdown"},"seo":{"title":"Shear/Blocking Panel Design Considerations","description":"Find product help, API documentation, and support resources for Simpson Strong-Tie projects."},"dynamicMarkdocComponents":[],"compilationErrors":[],"ast":{"$$mdtype":"Tag","name":"article","attributes":{},"children":[{"$$mdtype":"Tag","name":"Heading","attributes":{"level":1,"id":"shearblocking-panel-design-considerations","__idx":0},"children":["Shear/Blocking Panel Design Considerations"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Description"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Shear panels Similar in function to blocking panels, shear panels must be designed for drag loads. and blocking panels Trusses installed perpendicular to main span trusses intended to resist out of plane forces. Blocking panels typically do not have gravity or uplift loads applied. are similar in appearance and general function, however, shear panels must have a drag load applied as specified in the Construction Documents and/or by the Engineer of Record. Ensure that all required drag loads are applied in the Drag Load dialog and that bearings are defined only at the bottom chord."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Design Practices"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["When creating shear panel and blocking panel designs, review Construction Documents to determine if drag loads have been specified. When required, panels must be designed using the Drag Load macro. Refer to ",{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/shear-panels-settings"},"children":["EnvData settings"]}," to optimize shear panel workflow."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Notable Considerations:"]}]},{"$$mdtype":"Tag","name":"ul","attributes":{},"children":[{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Bearings should never be defined at the top chord of a panel."]}]},{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Drag load is always applied to the top chord of a shear panel component and resisted at the bottom chord."]}]},{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["How and where drag load is resisted along the bottom chord depends on Drag Load macro settings."]}]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Shear Panel/Blocking examples"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-shearblock-combined-ex.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Required Actions"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Blocking Panels"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Follow these design procedures when creating a blocking panel:"]},{"$$mdtype":"Tag","name":"ol","attributes":{},"children":[{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Enter the panel length in ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Span"]},"."]}]},{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Enter the panel height and top chord slope (generally zero) in the ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["TC Profile"]}," command line."]}]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-createblockingpanel.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/note-onlinehelp.png","alt":""},"children":[]}," ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Notes"]}]},{"$$mdtype":"Tag","name":"ul","attributes":{},"children":[{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Blocking panels created using this method receive the same loading as any common truss based on the component’s spacing (typically, 2’ o.c.). Since blocking panels are generally placed perpendicular-to and between adjacent trusses, they are not required to support vertical or wind loads."]}]},{"$$mdtype":"Tag","name":"li","attributes":{},"children":[{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Wind load applied to end verticals can be turned off by unchecking Apply to Left End Vert/Right End Vert in the ",{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/design-view/loading/wind-load"},"children":["Wind Load dialog"]},". Since blocking panels are usually relatively short and have a small span (< 2‘ in length), there is no need to take additional steps to adjust spacing, loading, or wind pressure on end verticals since it will not affect the final design. However, if the panels are relatively tall and wind pressure on the end verticals is creating high uplift reactions, those settings should be disabled."]}]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Shear Panels"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Shear panels are created using the same procedure as blocking panels. But in order to apply the required drag load, you must verify that the appropriate drag load magnitude (in LBS) or shear load (in PLF) is applied in the Drag Load macro."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-dragload-shearpanels.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/note-onlinehelp.png","alt":""},"children":[]}," ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Note:"]}," It is uncommon to have drag load required in LBS and PLF at the same time; only one should be used. Consideration must be given to how/where the drag load will be resisted along the bottom chord of the shear panel. If the panel bears directly on a continuous bearing wall/shear wall, the Continuous Shear Wall option should be checked."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-dragload-contshearwalls.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["If the Construction Documents do not clearly define how the shear panel is intended to resist the drag load, contact the Engineer of Record or Building Designer for clarification. In addition, for projects in snow load regions, there is a ",{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/design-view/loading/snow-load"},"children":["Snow Factor"]}," that can be applied. However, this does not typically apply to shear panels since these components are generally not required to support vertical loads."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-dragload-shearpanelschecked.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["The SP Command"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Use the TC Profile SP command to enable the Drag Load macro when entering the shear panel's design information."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-spcommand.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["The SP command uses the current EnvData settings at the time a shear panel design is created. Therefore, changes to your project-level EnvData settings should be made prior to creating shear panel designs."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Note that the SP command will automatically enable the Drag Load macro only when the EnvData setting for OneTrussControls > Auto-add drag load to Shear Panel? is set to true."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-autoenabledragload-envd.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["The drag load magnitude information (in LBS or PLF) for shear panels can be auto-populated in the Drag Load dialog based on the current EnvData > Dialogs > Drag Load > Drag Load in PLF for Shear Panels setting."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-dragload-plf-shearp-466x445.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Either LBS or PLF (typically, PLF) can be used for shear panels. Use whichever setting works best for your situation and ensure the value is 0.0000 in the other (unused) setting."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-lbs-dragload-469x448.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/transparent.gif","alt":""},"children":[]},{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["More about Shear Panel Creation"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["The EnvData > Plating > OverallCriteria > Plate Shear Panels Symmetrically setting, when set to True, ensures that symmetrical shear panels are analyzed and designed to accommodate upside-down and/or backward installation in the field."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-sp-installed-backwards-upsidedown-1167x440.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["A note is generated on the Truss Design Drawing (TDD) that states the component is ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Designed to allow upside-down and/or backward installation"]},", thus streamlining the inspection process. For shear panels that are not symmetrically designed, the TTD note will read ",{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Not designed for upside-down installation!"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-sp-note-backwards-upsidedown.png","alt":""},"children":[]}," ",{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-sp-note-no-backwards-upsidedown.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["The EnvData > LayoutSettings > ShearPanels settings allow you to further customize shear panels created in Layout. For example, the shear panel span can be automatically adjusted (reduced) in Layout view by a user-defined tolerance to facilitate installation."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Note that shear panels created in Layout view using the Shear Panel option will automatically use the SP command in the TC Profile command line. Whether a shear panel has been created in Design view using the SP command or created in Layout view using the Shear Panel option, a note displays on the TDD, below the Loads Summary."]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"img","attributes":{"src":"/images/csdirector-cstruss/resources/images/cr-loads-spblocking-note.png","alt":""},"children":[]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"strong","attributes":{},"children":["Related Topics"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/design-view/loading/drag-load"},"children":["Drag Loads"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Best Practices for Applying CS Truss Studio User Loads (2020-11-19)"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Quick Tip: Add blocks and shear panels in layout"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/edit-envdata-settings"},"children":["Edit Environment Data Settings"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Env Data Settings & Features"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":["Shear Panel Dialog"]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/env-data-settings/shear-panels-settings"},"children":["Shear Panel Settings"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/shear-panels/shear-panel-command"},"children":["Shear Panel command"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/shear-panels/create-shear-panels-design-view"},"children":["Create Shear Panels in Design View"]}]},{"$$mdtype":"Tag","name":"p","attributes":{},"children":[{"$$mdtype":"Tag","name":"MarkdownLink","attributes":{"href":"/csdirector-cstruss/help-center/truss-studio-online-help/shear-panels/create-shear-panels-blocks"},"children":["Create Shear Panels in Layout"]}]}]},"headings":[{"value":"Shear/Blocking Panel Design Considerations","id":"shearblocking-panel-design-considerations","depth":1}],"frontmatter":{"seo":{"title":"Shear/Blocking Panel Design Considerations"}},"lastModified":"2026-10-20T16:19:56.000Z","pagePropGetterError":{"message":"","name":""}},"slug":"/csdirector-cstruss/help-center/engineering-design-best-practices/cr-shear-blockingdesignconsiderations","userData":{"isAuthenticated":false,"teams":["anonymous"]},"isPublic":true}